Description
Fast processing of parameter and data of special modules
- Continually refreshes operation data of special module by CPU module
- Includes contact points such as conversion data of AD/DA module and command of HSC & positioning modules
Easy- to-use (Easy operation parameter setting and data monitoring)
- Convenient parameter setting available through XG5000
- Provides useful functions that can monitor and test operation data and contact points through XG5000
Simple maintenance (Changing online module)
- Without turning off and holding CPU, users can change special modules with ease.
Analog input/output module
Features
- Fast conversion processing
- High resolution
- Setting and monitoring special module parameters through XG5000
- Supports 4 types of digital output data formats
Analog input module
XGF-AV8A | 8 channels, voltage |
---|---|
XGF-AC8A | 8 channels, current |
XGF-AC8A | 8 channels, voltage/current |
XGF-AD16A | 4 channels, voltage/current |
XGF-AW4S | 16 channels, voltage/current |
Analog output module
XGF-DV4A | 4 channels, voltage |
---|---|
XGF-DC4A | 4 channels, current |
XGF-DV8A | 8 channels, voltage |
XGF-DC8A | 8 channels, current |
XGF-DV4S | 4 channels, voltage, Isolated |
XGF-DC4S | 4 channels, current, Isolated |
Analog input/output module
XGF-AH6A | Input: 4ch, Voltage/ Current Output: 2Ch Voltage/ Current |
---|
Temperature module
Features
- Insulation between channels
- Supports various input sensors (supporting C-type sensor)
- Various additional functions (average, filter, alarm, max/min value display)
- Special module parameter setting and monitoring with XG5000

Temperature input module
XGF-TC4S | 4 channels, thermocouple input, Isolated |
---|---|
XGF-RD4A | 4 channels, RTD input |
XGF-RD4S | 4 channels, RTD input, Isolated |

Temperature controller
XGF-RD8A | 8 channels input: RTD |
---|---|
XGF-TC4UD | 4 channels input: voltage/current/TC/RTD 8 channels output: current/TR |
XGF-TC4RT | 4 channels input: RTD 4 channels output: TR Control: 4loop |
High speed counter module
Features
- Parameter setting and monitoring using XG5000
- Incremental encoder available
- Supporting various pulse input (5V, 12V, 24V)
- Various multiplication (1/2 phase pulse input)
- External present input
- Provides functions to prevent counting external signals
- Supports HTL-level incremental encoder in the line-drive input type
.png)
High-speed counter module
XGF-HO2A | 2 channels, Open collector |
---|---|
XGF-HD2A | 2 channels, Line driver |
XGF-H08A | 8-channels high speed counter module, 8Ch |
HART interface analogue/digital conversion module (XGF-AC4H, XGF-DC4H)
Features
- It supports HART protocol in the input range of 4~20mA, bi-directional digital communication is available using analog signal wiring. If analog wiring is currently used, there is no need to add wiring for HART communication (HART communication is not supported in the range of 0~20mA)
- High accuracy
- Operation parameters setting/monitoring
- Input disconnection detection function

Event input module (XGF-SOEA)
Features
- SOE: Sequence Of Events Recorder
- I/O information collection to analyze the control system in Generation and Transformer
- Event collection in every 1ms
- Max. 300ea data available
- Data retain by built-in memory
- Max. installable module: 16ea
- Event monitoring of history through SOE Viewer

Datalog module (XGF-DL16A)
Features
- Saves PLC device data without PC
- Saves PLC control data without missing any change
- Data can be saved whenever scanning is done or they can be saved at an interval of several ms(milliseconds).
- Saves a large volume of data files
- Long-term data saving is available since CF card and USB memory with a large volume of up to 16GB can be used.

Reviews
There are no reviews yet.